Deutsche Version  Deutsche Version
Contact to Gaskatel  Contact gaskatel forum Forum
Gaskatel GmbH - Home
Reference projekt 5:

Zinc/Air-Batteries as a Sensor for Oxygen


Varta Batterie GmbH (1998-1999)

Gaskatel was assigned by the company Varta to test the application of modified Zinc/Air Batteries as an oxygen sensor. We tested the cells regarding linearity, response time, selectivity, influence of pressure and temperature. We also appraised their start performance and their efficacy as a detector of dissolved oxygen. The material of the sensor as well as the diffusion barrier were varied.

When we presented the Prototype at the Sensor Fair (Sensor Messe) in Nuremberg it emerged as an eye catcher. Because of its possible mass production by Varta this oxygen sensor has the potential to enable a low-priced measurement of breathing air.

This sensor could definitely be used in medical technology or for interior air monitoring or related applications. Unfortunately this product is not yet available. To make it ready for the market it would be necessary to find the right partner consortium.



back to References

copyright © gaskatel GmbH, 2003, home, email