ElyFlow Starterkit
Electrochemical test cell
Item number: 83499
HS code: 90309000
Country of origin: Germany
🔝Instead of 6.631,80 € only 5.299,- €🔝
ElyFlow Starterkit – Everything you need in one package!
ElyFlow is optimized for electrolyte circulation.
This cell is suitable for all flat materials.
Common sources of error such as IR drop, field line curvature, and boundary effects caused by the sealing are minimized. The Haber-Luggin capillary is drilled laterally at a fixed distance from the working electrode.
Gas supply to the working electrode is possible, making ElyFlow also suitable for measurements on gas diffusion electrodes.
Active Area: 10 cm2
Electrolyte Volume: 25 ml
Material: PTFE
Max. Temperature with electrolyte flow: 90°C
Max. Temperature without electrolyte flow: 150°C
This set includes an additional analyte compartment and the Gaskatel control box ElyControl (24 V, 500 W).
Because only a well-regulated temperature ensures comparable measurement results!
Two separate controlled PID temperature controller may adjust anolyte and catholyte temperature separately.
Two pump controller allow to adjust an electrolyte flow through the cells to remove products like gas bubbles or liquid products.
An internal galvanostat (0 - 5 Ampere) allows simple electrochemical experiments.
Free software GCB to run the experiments and store the datas in a sql database.
A suitable reference electrode with test lead is also included. The Mini-HydroFlex is located in a separate reservoir so that the flow of the streamline is not disturbed.
Besides, two heatable beakers (400 ml) made of PTFE with integrated PTC Heating elements (24 V) are included.
1 x Test cell ElyFlow PTFE consisting of
1 x Working electrode holder PTFE (83420-v02-PTFE)
1 x Analyte compartment PTFE (83430)
1 x Counter electrode holder PTFE (83410) with integrated
1 x Heating element
1 x Counter electrode Nickel (80178)
1 x Counter electrode MMO (80182)
2 x Test lead red (89017)
2 x Test lead black (89019)
2 x Connection coupling adapter red (89037)
2 x Connection coupling adapter black (89038)
1 x Hexagon socket spanner 6 x125 mm 6 okt. (83011)
2 x O-Ring 39.69 x 3.53 mm FKM (80357)
1 x O-Ring 53.57 x 3.53 mm FKM (80356)
1 x Manual
1 x Analyte Compartment made of PTFE with
2 x Straight connector for hoses (80013)
3 x Screw plug (80031)
1 x O-ring 53.57 x 3.53 mm EPDM (80066)
1 x O-ring 39.69 x 3.53 mm EPDM (80560)
2 x Silicone sealing for ElyFlow (83401)
4 x Thumb screw M8 x 80 PA6.6 (83005)
1 x Cation exchange membrane (80610-EF)
1 x O-Ring 39.69 x 3.53 mm FKM (80357)
1 x O-Ring 53.57 x 3.53 mm FKM (80356)
1 x Gaskatel Control box ElyControl
1 x Test lead red 750 mm (89031)
1 x Test lead black 750 mm (89032)
2 x Electrolyte pump (83720) with hose clamps (80169)
2 m Hose made of TPE (80190)
2 x Pt-100 resistance temperature detector FEP insulated (83911)
1 x Power cord
1 x Mini-HydroFlex hydrogen reference electrode (81020)
1 x Hydrogen cell (80521)
1 x Activation sticker (80077)
1 x Manual
1 x Test lead 2/4 blue (89010)
2 x Heatable Beaker 400 ml PTFE (83730)
- Weight: 6625 g
Description ElyFlow
ElyFlow is a test cell optimized for electrolyte circuits for electrochemistry with a three-electrode set-up.
To achieve comparable results, you need a cell design with defined geometric parameters.
ElyFlow is also flexible regarding to the sample (e.g. metal sheet, foils, gas diffusion electrode) – but rigid where it really counts: the distance between the working and counter electrode is fixed and thus defined as well as the distance between the working electrode and reference electrode.
Since ElyFlow is made of PTFE (polytetrafluorethylene), it is chemical resistant.
The plastics have no influence on the field line distribution.
ElyFlow can be used in a pH range of pH 10 to pH 16 by using the inserted nickel counter electrode.
For measurements in an pH range pH -2 to pH 10 you have to use the MMO counter electrode.
The electrolyte volume of the cell itself is only 25 ml.
By using external beakers and pumping systems, measurements with significantly larger electrolyte volumes are possible.

Technical Data ElyFlow
Subject to technical changes.
Specifications
|
Description
|
|---|---|
Material | PTFE (Polytetrafluorethylene) |
Counter Electrode | Nickel (80178) for the pH range from pH 10 to pH 16 |
Material O-rings | EPDM (Ethylene-Propylene-Diene-Monomer-rubber) For use in acids, please replace the built-in EPDM O-rings with the enclosed FKM O-rings. |
Material Sealings | Silicone For poorly conductive electrodes, please purchase the following sealing: |
pH range | pH -2 to pH 16 |
Electrolyte Volume | 25 ml |
Sample Size | 6.4 cm x 7 cm |
Active Area | 10 cm2 |
Heating Element | 70 W |
Max. Temperature | With electrolyte flow: 90°C |
Technical Data Mini-HydroFlex
Subject to technical changes.
Specifications
|
Description
|
|---|---|
Material Shaft | PEEK (Polyetheretherketone) |
Material Head | PTFE (Polytetrafluorethylene) |
Shaft Diameter | 1.6 mm |
Shaft Length | 50 +/- 1 mm The length of the reference electrode Mini-HydroFlex can be customized to your requirements for an additional charge. |
Diameter Head | 20 mm |
Sealings | Fluor rubber |
Height Head | 30 mm plus 5.5 mm for cell holder |
Thread | G1/8″ |
Contact Socket | Gold-plated socket for 2 mm plugs |
Sensor Element | Palladium gas diffusion electrode |
Hydrogen Source | Replaceable hydrogen cell (80521) |
Max. Temperature | 160°C as long as only the PEEK shaft is exposed to this temperature |

Technical Data ElyControl
Subject to technical changes.
Specifications
|
Description
|
|---|---|
Control Units for Electrolyte Pumps (83720) | 0 - 100 ml/min |
Power Supply | 24 V |
Temperature Control | PID |
Galvanostat | 0 - 5 Ampere |
Technical Data Heatable Beaker
Subject to technical changes.
Specifications
|
Description
|
|---|---|
Volume | 400 ml |
PTC Heating Element | 24 V |
Material | PTFE (Polytetrafluorethylene) |
Commissioning of the Hydrogen Reference Electrode Mini-HydroFlex
Comparison of our Electrochemical Test Cells
Spare Parts
Some parts of our electrochemical test cells wear out over time, so you should replace them in a timely manner.
Recommended Accessories
Do you have problems with reaction products from the counter electrode?
Very aggressive ions are often generated at the counter electrode. Even small quantities may lead to corrosion on the working electrode.
Therefore, Gaskatel offers an additional analyte compartment.
One analyte compartment is included in the scope of delivery of our test cell ElyFlow. However, you can implement up to three!
A membrane is inserted between the analyte and counter electrode compartment. This membrane separates anolyte and catholyte. The working electrode is thus protected from the reaction products of the counter electrode.

Would you like to learn more about our test cell ElyFlow?

Electrochemical test cell ElyFlow
ElyFlow is a test cell optimized for electrolyte circuits for electrochemistry with a three-electrode set-up. Here you can find some general information.

Features of our Electrochemical Test Cell ElyFlow
We have developed Elyflow for long term measurements with pumped electrolyte. Here you will find information on the the three-electrode set-up of ElyFlow. Learn more about what influences the electric field.

How to Work with ElyFlow
Here you will find information on commissioning, maintenance and troubleshooting of the electrochemical test cell ElyFlow.
Would you like to learn more about the hydrogen reference electrode Mini-HydroFlex?

How to Work with the Hydrogen Reference Electrode Mini-HydroFlex
Here you will find information on commissioning, maintenance and troubleshooting of the hydrogen reference electrode Mini-HydroFlex.

Checking the Functionality of Mini-HydroFlex
Ideally, you should check the hydrogen electrode against a so-called master electrode, e.g. a calomel electrode, before your actual measurements. Here you will find more information about checking your HydroFlex or Mini-HydroFlex.

Use of the Hydrogen Electrode Mini-HydroFlex
Here you will find out more about the electrolytes and solutions in which our hydrogen reference electrodes can be used. Also learn more about the use of Mini-HydroFlex as a Reversible Hydrogen Electrode, Normal Hydrogen Electrode, and Standard Hydrogen Electrode.
You may also like
Heatable vessel made of PTFE. Liquid quantity: 0.7 - 1.2 liter. Max. media temperature: 80°C. Suitable accessory for electrolyte circuits with voltammetric cell ElyFlow.
Working electrode holder made of PMMA suitable for the gas supply for ElyFlow. It can be used for temperatures of up to 80°C.
Pump adjustable with power supply unit and EPDM membrane. pH range: pH 2 to 16. For hoses: 6/4 mm. Max. temperature: 95°C. Not recommended for strong acids.
Still Questions?
Our FAQ section helps you to solve problems quickly and easily.
Browse through the following categories and find the right answer to your question.
If you have any further questions, please feel free to contact us.
You are also welcome to take a look at our guides and FAQ section.